DOI | Resolve DOI: https://doi.org/10.1109/CPEM.2012.6250875 |
---|
Author | Search for: So, Eddy1; Search for: Arseneau, Rejean1; Search for: Angelo, Dave1 |
---|
Affiliation | - National Research Council of Canada. Measurement Science and Standards
|
---|
Format | Text, Article |
---|
Conference | CPEM 2012, 2012 Conference on Precision Electromagnetic Measurements, July 1-6, 2012, Washington, DC, United States |
---|
Subject | current-comparator; power bridge; power standard; uncertainty |
---|
Abstract | An improved power standard derived from a current comparator power bridge for calibrating active/reactive power and energy meters under sinusoidal conditions is described. Measurements can be made at any power factor from zero lag through unity to zero lead, positive or negative power, at 120 V, 5 A, and 50 or 60 Hz. The improved power standard has an estimated basic uncertainty of 2.5 μW/VA at k = 1. |
---|
Publication date | 2012 |
---|
Publisher | IEEE |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 21269103 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 049d3626-4f54-41f3-b659-79d878f71fae |
---|
Record created | 2013-12-05 |
---|
Record modified | 2024-03-07 |
---|