DOI | Resolve DOI: https://doi.org/10.1117/12.243034 |
---|
Author | Search for: Liu, Hui; Search for: Wilson, P.; Search for: Buchanan, Margaret1; Search for: Khanna, Shyam; Search for: Dereniak, Eustace; Search for: Sampson, Robert |
---|
Affiliation | - National Research Council of Canada. NRC Institute for Microstructural Sciences
|
---|
Format | Text, Article |
---|
Abstract | We report on the experimental results of the effect of proton radiation on the performance of quantum well infrared photodetectors. A range of energies from 0.8 to 10 MeV and a range of fluences from 1012 to 1016 cm-2 were used. The detector performance are characterized by its responsivity becomes progressively worse with increasing fluence. For the same fluence, lower energy causes more damage to the detector. |
---|
Publisher | SPIE |
---|
Place | Orlando, FL, USA |
---|
NPARC number | 12338972 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 188d0f52-476c-4166-8dc6-a39a4ce3b1ce |
---|
Record created | 2009-09-11 |
---|
Record modified | 2020-04-16 |
---|