DOI | Resolve DOI: https://doi.org/10.1109/CPEM.2014.6898401 |
---|
Author | Search for: Shan, Yueyan; Search for: Meng, Yu Song; Search for: Filipski, Piotr S.1 |
---|
Affiliation | - National Research Council of Canada. Measurement Science and Standards
|
---|
Format | Text, Article |
---|
Conference | 29th Conference on Precision Electromagnetic Measurements, CPEM 2014, 24 August 2014 through 29 August 2014 |
---|
Subject | CTVC; Linearity; RF-DC transfer difference; Thermal voltage converters; Mathematical models |
---|
Abstract | Linearity analysis of a calorimetric thermal voltage converter (CTVC) designed by the National Research Council of Canada for RF-DC transfer difference up to 1 GHz is presented in this paper. At higher frequencies, the CTVC is evaluated in terms of the calibration factor of a RF power sensor and the reflection coefficients at its Type-N connector. Good performance has been observed which indicates that CTVC could be a potential candidate for calibrating RF power sensors in terms of its RF-DC transfer difference. |
---|
Publication date | 2014-08 |
---|
In | |
---|
Series | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 21272713 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 23ab5e0f-4688-4571-a200-9eb15721b49d |
---|
Record created | 2014-12-03 |
---|
Record modified | 2020-04-22 |
---|