Abstract | At the NRC we are performing the first accuracy evaluation of our newly developed caesium fountain clock, NRC-FCs2. This primary frequency standard operates with a short term stability and upon full evaluation, we expect to achieve a type B uncertainty in fractional frequency below 5x10⁻¹⁶. We will discuss the current status of the evaluation, including several evaluated shifts, as well as the outstanding systematics yet to be fully characterized. |
---|