Abstract | The purpose of this research was to develop performance guidelines for the selection of hot-poured bituminous crack sealants at low temperature. This was accomplished by measuring the mechanical properties of crack sealant at low temperature and then developing performance criteria for material selection. The modified direct tension test (DTT), crack sealant direct tension test (CSDTT), simulates the in-situ loading behavior of crack sealants in the laboratory. |
---|