Download | - View accepted manuscript: AC shunt calibrations at NRC (PDF, 844 KiB)
|
---|
Author | Search for: Filipski, Peter S.1; Search for: Boecker, Michael1 |
---|
Affiliation | - National Research Council of Canada. NRC Institute for National Measurement Standards
|
---|
Format | Text, Article |
---|
Conference | 2010 NCSL International Workshop and Symposium, July 25-29, 2010, Providence, Rhode Island, USA |
---|
Abstract | NRC offers calibration of ac shunts from milliamperes up to 100 A, in the 10 Hz to 100 kHz frequency band with expanded uncertainties between 10 A/A for currents in the milliampere range to 50 A/A at 100 A and 100 kHz. The paper describes the design of NRC ac standard shunts, as well as NRC experience in calibrations of commercial shunts. The ac-dc difference of some commercial low current shunts is load sensitive at higher frequency ranges. The paper discusses reasons for this sensitivity and suggests mitigating solutions. |
---|
Publication date | 2010-08-25 |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 18116650 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 4c78bc64-0773-48d1-aa1b-df171459ad85 |
---|
Record created | 2012-03-09 |
---|
Record modified | 2020-04-17 |
---|