Download | - View final version: Non-sequential design of a thermal radiative baffle for NFIRAOS (PDF, 3.7 MiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.1117/12.2285901 |
---|
Author | Search for: Atwood, Jenny1; Search for: Herriot, Glen1; Search for: Crane, Jeffrey1 |
---|
Editor | Search for: Pfisterer, Richard N.; Search for: Rogers, John R.; Search for: Muschaweck, Julius A.; Search for: Clark, Peter P. |
---|
Affiliation | - National Research Council of Canada. Herzberg Astronomy and Astrophysics
|
---|
Format | Text, Article |
---|
Conference | International Optical Design Conference 2017, July 9-13, 2017, Denver, Colorado, United States |
---|
Abstract | NFIRAOS, the first-light adaptive optics system for the Thirty Meter Telescope (TMT), has a cooled optical enclosure at -30 deg C with an evacuated, double-pane window to allow light in. NFIRAOS has chosen a radiative baffle design between the windows to mitigate frosting of the outer window and to avoid convective turbulence on either window. Here, we present the design of the baffle and the non-sequential analysis showing sufficient radiation rejection. |
---|
Publication date | 2017-11-27 |
---|
Publisher | Society of Photo-Optical Instrumentation Engineers (SPIE) |
---|
Licence | - Copyright 2017 Society of Photo‑Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this publication for a fee or for commercial purposes, and modification of the contents of the publication are prohibited.
https://www.spiedigitallibrary.org/article-sharing-policies?SSO=1
|
---|