| Download | - View accepted manuscript: High voltage divider calibration with the reference step method (PDF, 773 KiB)
|
|---|
| Author | Search for: Parks, harold1 |
|---|
| Affiliation | - National Research Council of Canada. Measurement Science and Standards
|
|---|
| Format | Text, Article |
|---|
| Conference | NCSL International Workshop and Symposium, July 19-23, 2015 Grapevine, Texas |
|---|
| Abstract | High voltage DC measurements, from 10 kV up to several hundred kV, are usually traceable through resistive dividers which have a divider ratio on the order of 10 000 to 100 000. The reference step method providers a highly accurate ratio metric method of calibrating 1000 V calibrators across a wide range of voltages. We adapt this method for measuring the ratio of high voltage dividers at low (equal or less than 1000 V) voltages as a first step to establishing traceability at high voltages. |
|---|
| Publication date | 2015-07 |
|---|
| In | |
|---|
| Language | English |
|---|
| Peer reviewed | Yes |
|---|
| NPARC number | 21276426 |
|---|
| Export citation | Export as RIS |
|---|
| Report a correction | Report a correction (opens in a new tab) |
|---|
| Record identifier | 6c5dca82-886c-4630-a15f-1a6f675b9a10 |
|---|
| Record created | 2015-10-13 |
|---|
| Record modified | 2020-06-04 |
|---|