Abstract | The use of a standard one-turn potentiometer to measure wind direction can create a problem because of the discontinuity in the potentiometer signal when the sliding contact passes from the maximum output level across the gap to the lowest output level, or vice versa. This results in an error in the calculation of the mean. This Note discusses a method of determining the effect of the gap by examining the measured mean and standard deviation of the wind direction signal. |
---|