| Download | - View final version: A pulse stretching circuit (PDF, 1.2 MiB)
|
|---|
| DOI | Resolve DOI: https://doi.org/10.4224/40004042 |
|---|
| Author | Search for: Hammell, T.H.1 |
|---|
| Affiliation | - National Research Council Canada. Division of Mechanical Engineering
|
|---|
| Format | Text, Memorandum |
|---|
| Physical description | 8 p. |
|---|
| Abstract | A set of contacts with a current limitation of 0.01 amperes and an open time of .003 seconds between switch positions was to operate a relay whose fall-out time was as high as 0.015 seconds after the removal of the hold in voltage. The circuit described here was designed to accommodate these parameters and operated satisfactorily. |
|---|
| Date published | 1967-10 |
|---|
| Publisher | National Research Council Canada |
|---|
| Series | |
|---|
| Language | English |
|---|
| Peer reviewed | No |
|---|
| Export citation | Export as RIS |
|---|
| Report a correction | Report a correction (opens in a new tab) |
|---|
| Record identifier | 91e0f64a-df05-484b-af3d-7030194384d5 |
|---|
| Record created | 2026-05-13 |
|---|
| Record modified | 2026-05-13 |
|---|