Author | Search for: Djokic, Bran Islav1; Search for: Parks, Harold1 |
---|
Affiliation | - National Research Council of Canada. Measurement Science and Standards
|
---|
Format | Text, Article |
---|
Conference | Conference on Precision Electromagnetic Measurements, July 8-13, 2018, Paris, France |
---|
Subject | AC shunt; current measurement; measurement standards; calibration; measurement uncertainty; current comparator; calculable resistor |
---|
Abstract | This paper describes a calibration system for AC shunts using digital sampling. It provides bot h ratio errors and phase displacements of a shunt under test with respect to a reference shunt. ln its basic configuration, the calibration system operates at currents of up to 10 A and frequencies of up to IO kHz. The expanded uncertainties (k = 2) of the described calibration system arc estimated to be better than 30 µA/A for magnitude and 30 µrad for phrase at 10 kHz, and lower than these at lower frequencies. |
---|
Publication date | 2018-07 |
---|
Publisher | The Conference |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 23004093 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | b470b4c1-35b4-4a41-80af-17d3ba384957 |
---|
Record created | 2018-09-27 |
---|
Record modified | 2020-03-16 |
---|