Download | - View final version: How to ensure good thermal performance of blown mineral fibre insulation in horizontal and vertical installations (PDF, 3.9 MiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.4224/40000543 |
---|
Author | Search for: Bomberg, M. T.1; Search for: Solvason, K. R. |
---|
Affiliation | - National Research Council of Canada. NRC Institute for Research in Construction
|
---|
Format | Text, Article |
---|
Physical description | 28 p. |
---|
Subject | Fibre; thermal insulation; thermal insulating materials; thermal resistance; installation (activity); insulating (activity); insulation contractors; density (physics) |
---|
Abstract | This paper is concerned with the thermal performance of blown Mineral Fibre Insulation (MFI), and more specifically with the question of how to ensure that the purchaser receives the amount of thermal resistance contracted for. It is shown that, owing to the variability of the material and installation techniques, two requirements must simultaneously be fulfilled at the time of installation: ( i) minimum installed thickness; and (ii) minimum mass per unit area. This Note deals with the determination of these minimum values, and the sample preparation and laboratory testing of the thermal resistance of MFI. |
---|
Publication date | 1980-12 |
---|
Publisher | National Research Council of Canada |
---|
Series | |
---|
Language | English |
---|
Peer reviewed | No |
---|
NRC number | NRC-IRC-3536 |
---|
NPARC number | 20375811 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | beb6ae92-8fdc-491c-8042-57239b9f31e0 |
---|
Record created | 2012-07-23 |
---|
Record modified | 2023-01-18 |
---|