DOI | Resolve DOI: https://doi.org/10.1109/CPEM.2012.6250693 |
---|
Author | Search for: Yang, Lin; Search for: Bai, Jingfen; Search for: So, Eddy |
---|
Format | Text, Article |
---|
Conference | CPEM 2012, 2012 Conference on Precision Electromagnetic Measurements, July 1-6, 2012, Washington, DC, United States |
---|
Subject | current-comparator; power bridge; power standard; uncertainty |
---|
Abstract | A reactive power standard, based on the current comparator power bridge, established at CEPRI, for calibrating active/reactive power/energy meters under sinusoidal conditions is described. It allows calibration of active/reactive power and energy meters at voltages between 60 V to 600 V and currents between 0.1 A to 200 A, any power factor from zero lag through unity to zero lead, and test frequencies of 45 Hz to 65 Hz. The Type B uncertainty of the reactive power standard is estimated to be 30 μvar/VA at k = 2. A comparison of reactive power meter calibrations between CEPRI and NRC will also be presented and discussed, including the sources of errors and corresponding uncertainties. |
---|
Publication date | 2012 |
---|
Publisher | IEEE |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 21269095 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | ccfc8342-fb92-46e4-96e6-1a14b622e8d4 |
---|
Record created | 2013-12-05 |
---|
Record modified | 2024-03-07 |
---|