Alternative title | Sampling current ratio bridge for calibration of current transducers up to 10 kA with 5 5 · 1o-6 Uncertainty |
---|
Download | - View accepted manuscript: Sampling current ratio bridge for calibration of current transducers up to 10 kA with 5 ppm uncertainty (PDF, 1.5 MiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.1109/CPEM.2014.6898232 |
---|
Author | Search for: van den Brom, Helko E.; Search for: Rietveld, Gert; Search for: So, Eddy1 |
---|
Affiliation | - National Research Council of Canada. Measurement Science and Standards
|
---|
Format | Text, Article |
---|
Conference | 29th Conference on Precision Electromagnetic Measurements, CPEM 2014, 24 August 2014 through 29 August 2014 |
---|
Subject | Electric instrument transformers; Sampling; Current ratios; Current transducer; uncertainty; Electric current measurement |
---|
Abstract | A sampling current ratio bridge has been developed, tested and validated for the accurate complex ratio measurement of AC current transducers for primary currents up to 10 kA with expanded uncertainties of 5 · 10-6 in magnitude and 5 μrad in phase (k = 2). A unique property of the system is the use of digitizers for sampling of the secondary current signals and step-down transformers with a large number of current ratios. This allows for the accurate calibration of a large variety of different current transformers and other types of current transducers. |
---|
Publication date | 2014-08 |
---|
In | |
---|
Series | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 21272619 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | d03e1b81-dc1d-4fd9-8b22-0b3d36d2b4db |
---|
Record created | 2014-12-03 |
---|
Record modified | 2020-06-04 |
---|