Téléchargement | - Voir la version finale : Performance of a CO 2 -based demand controlled dual core energy recovery ventilation system for northern housing experiencing varying occupancy (PDF, 4.3 Mio)
|
---|
DOI | Trouver le DOI : https://doi.org/10.1051/e3sconf/202339601002 |
---|
Auteur | Rechercher : Ouazia, Boualem1; Rechercher : Arsenault, Chantal1; Rechercher : Brhane, Sador1; Rechercher : Lefebvre, Daniel1; Rechercher : Nong, Gang1; Rechercher : Mancini, Sandra1; Rechercher : Tardif, Patrique1 |
---|
Affiliation | - Conseil national de recherches du Canada. Construction
|
---|
Format | Texte, Article |
---|
Conférence | 11th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings (IAQVEC2023), May 20-23 2023, Tokyo, Japan |
---|
Sujet | air quality; indoor air pollution; energy engineering |
---|
Résumé | Indoor air quality and health are major areas of concern in northern and remote communities where homes experience varying occupancy, often overcrowding and are influenced by ventilation. Heat/energy recovery ventilators installed in the north are selected to provide required minimum ventilation rate set by ventilation standards (ASHRAE 62.2, etc.). Northern overcrowded homes become under-ventilated, leading to deteriorated IAQ, mold and health-related problems. This paper present results from a side-by-side testing of a CO₂-based demand-controlled ERV versus a constant air flows ERV, using twin houses with simulated occupancies. The control strategy was based on the difference in CO₂-concentration between exhaust/return air from the house and outdoor air. The implemented strategy based on a CO₂ sensor network connected with an ERV continuously exhausting stale air from kitchen and bathrooms was simple and efficient in adjusting ventilation rate based on occupancy rate. The CO₂-based demand-controlled ERV provided a much better control of indoor CO₂ concentrations in the main floor and master bedroom, and with lower CO₂ concentrations in bedrooms during night time, compared to the reference house with concentrations exceeding 2000 ppm. However, the CO₂-based demand-controlled ERV had higher power consumption than conventional ERV with constant air flows. |
---|
Date de publication | 2023 |
---|
Maison d’édition | EDP Sciences |
---|
Licence | |
---|
Dans | |
---|
Langue | anglais |
---|
Identificateur | e3sconf_iaqvec2023_01002 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 71c908e6-f4c9-4c4b-b21e-9b041848d6fa |
---|
Enregistrement créé | 2024-07-15 |
---|
Enregistrement modifié | 2024-07-15 |
---|