DOI | Trouver le DOI : https://doi.org/10.23919/USNC/URSI49741.2020.9321632 |
---|
Auteur | Rechercher : Hesari, Sara Salem; Rechercher : Caputa, Krzysztof1 |
---|
Affiliation | - Conseil national de recherches du Canada. Herzberg en astronomie et en astrophysique
|
---|
Format | Texte, Article |
---|
Conférence | 2020 IEEE USNC-CNC-URSI North American Radio Science Meeting (Joint with AP-S Symposium), July 5-10, 2020, Montreal, QC, Canada |
---|
Sujet | anechoic chamber; RFI measurements; EMI; clock synthesizer; SKA; electromagnetic interference; clocks; Frequency measurement; synthesizers; sensitivity; power measurement |
---|
Résumé | This paper identifies sources of EMI emissions of the SKA-mid Receiver Sampler for SKA frequency Bands 1 to 3 (RXS123) and describes the EMI test facilities and test process for the digitizer prototype. The RXS123 must satisfy very strict EMI radiation and susceptibility standards listed in the SPF Receiver Requirement Specification. The digitizer architecture has been designed from the ground up to meet these EMI requirements. This paper presents the radiated RFI measurements of the RXS123 focusing on the clock synthesizer and ODL board from 50 MHZ to 8.7 GHz. |
---|
Date de publication | 2020-07-05 |
---|
Maison d’édition | IEEE |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 34593ca3-585e-4455-ad44-4f003daf0500 |
---|
Enregistrement créé | 2022-06-24 |
---|
Enregistrement modifié | 2022-06-24 |
---|