Auteur | Rechercher : Fry, C.; Rechercher : Sun, Z.1 |
---|
Affiliation | - Conseil national de recherches du Canada. Institut des matériaux industriels du CNRC
|
---|
Format | Texte, Article |
---|
Conférence | 70th Annual Technical Conference of the Society of Plastics Engineers 2012, ANTEC 2012, 2 April 2012 through 4 April 2012, Orlando, FL |
---|
Sujet | Calibration process; Filler concentration; In-line; Novel techniques; Polymer flows; Ultrasonic inspections; Carbon black; Fillers; Plastic products; Polymers; Ultrasonic testing; Filled polymers |
---|
Résumé | A novel technique for ultrasonic determination of filler concentration in polymers has been proposed and tested. The new technique senses the overall effect of the filler on the polymer flow behavior and uses this effect to infer the filler concentration. An in-line calibration process has been proposed and implemented for the application of the technique. An average estimation accuracy of better than 0.4% in weight on filler concentration has been achieved. |
---|
Date de publication | 2012 |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21269385 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 360680d5-6102-417c-82c6-e17f4e3581d5 |
---|
Enregistrement créé | 2013-12-12 |
---|
Enregistrement modifié | 2020-04-21 |
---|