Autre titre | Production of a carrier-free standard 56Mn source for the NRC manganese salt bath |
---|
DOI | Trouver le DOI : https://doi.org/10.1016/j.apradiso.2019.108896 |
---|
Auteur | Rechercher : Galea, R.1; Rechercher : Moore, K.1 |
---|
Affiliation | - Conseil national de recherches du Canada. Science des mesures et étalons
|
---|
Format | Texte, Article |
---|
Conférence | International Conference on Radionuclide Metrology, May 27-31, 2019, Salamanca, Spain |
---|
Description physique | 13 p. |
---|
Sujet | Mn salt bath; Neutron emission rate; ⁵⁶Mn; Szilard-Chalmers |
---|
Résumé | The National Research Council (NRC) of Canada's primary method for emission rate for radionuclide neutron sources utilizes a manganese salt bath which was last calibrated in the 1960s. At that time, an NRC RaBe neutron source was used to irradiate a solution of calcium permanganate to take advantage of the Szilard-Chalmers effect in producing the bulk ⁵⁶Mn material for standardization and calibration of the bath. When attempting to repeat this exercise, a small amount (∼100 kBq) was produced. This amount was sufficient for the standardization process but did not yield enough material to calibrate the bath to a sufficient level of precision.
Improvements upon the previous separation scheme adopted at NRC for the separation of the ⁵⁶Mn from the bulk irradiated material included the rinsing of the ⁵⁶Mn dioxide precipitate using a mixture of sulfuric acid and hydrogen peroxide. While these improvements made in the separation chemistry improved the yield of ⁵⁶Mn extraction from 60% to above 95% the maximum amount of activity was still quite low. Hence in March of 2018, the SLOWPOKE-2 Facility at the Royal Military College in Kingston, ON, was used to irradiate three vials of KMnO4 in solution. An estimated 2 GBq was produced and sent to NRC, from which the extraction procedure recovered essentially all of the available ⁵⁶Mn.
The ⁵⁶Mn was standardized using the πβ−γ anti-coincidence counting system and confirmed using the CIEMAT/NIST primary method. The resulting bulk material was certified with an uncertainty of 0.8% (k = 2). Minor quantities of ⁶⁵Zn,⁶⁹mZn and 42K were unexpectedly observed but were in minute quantities so as not to affect the results of the standardization or calibration. The standardized ⁵⁶Mn artifact was used to calibrate the Secondary Standard Ionizing Radiation Chamber System (SSIRCS) for a more rapid deployment of the calibrant in the future. |
---|
Date de publication | 2019-09-16 |
---|
Maison d’édition | Elsevier |
---|
Dans | |
---|
Note | yes |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 495c2f76-464b-4fa2-96f7-4805948c0541 |
---|
Enregistrement créé | 2019-09-26 |
---|
Enregistrement modifié | 2021-08-23 |
---|