| Téléchargement | - Voir la version finale : The transmission loss of 203 mm thick prestressed precast concrete hollowcore floors (PDF, 641 Kio)
|
|---|
| DOI | Trouver le DOI : https://doi.org/10.4224/23002895 |
|---|
| Auteur | Rechercher : Mahn, Jeffrey1 |
|---|
| Affiliation | - Conseil national de recherches Canada. Construction
|
|---|
| Format | Texte, Rapport technique |
|---|
| Sujet | hollowcore; STC; IIC; precast concrete; CPCI; sound transmission class |
|---|
| Résumé | The transmission loss and impact insulation of floors comprised of 203 mm (8 in) thick precast/prestressed concrete hollowcores slabs were evaluated in the direct floor testing facility at the National Research Council. The first floor of concrete hollowcore slabs had a mass per unit area of 269 kg/m2 without grout and a mass per unit area of 273 kg/m2 once the grout was applied between the slabs. The second floor of concrete hollowcore slabs had a mass per unit area of 301 kg/m2 without grout and a mass per unit area of 305 kg/m2 once the grout was applied between the slabs. This floor was also tested with a 25.4 mm (1") underlayment which was poured directly onto the concrete hollowcore slabs and with a carpet and underpad on the underlayment. |
|---|
| Date de publication | 2018-03-28 |
|---|
| Maison d’édition | National Research Council of Canada. Construction |
|---|
| Série | |
|---|
| Note | Sur la page de titre: Canadian Precast/Prestressed Concrete Institute |
|---|
| Langue | anglais |
|---|
| Publications évaluées par des pairs | Non |
|---|
| Numéro NPARC | 23002895 |
|---|
| Exporter la notice | Exporter en format RIS |
|---|
| Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
|---|
| Identificateur de l’enregistrement | 59bb30be-b77c-4df7-b739-b0343a1a34f2 |
|---|
| Enregistrement créé | 2018-03-21 |
|---|
| Enregistrement modifié | 2022-06-09 |
|---|