DOI | Trouver le DOI : https://doi.org/10.1016/j.measurement.2012.03.008 |
---|
Auteur | Rechercher : Filipski, Piotr S.1; Rechercher : van den Brom, Helko E.; Rechercher : Houtzager, Ernest |
---|
Affiliation | - Conseil national de recherches du Canada. Science des mesures et étalons
|
---|
Format | Texte, Article |
---|
Conférence | XVIII TC4 IMEKO Symposium and IX Semetro, September 2011, Natal, Brazil |
---|
Sujet | Josephson arrays; Signal synthesis; Standards; AC voltage standard |
---|
Résumé | This paper presents results of an international comparison of two quantum AC voltage standards based on pulse-driven Josephson arrays. The two systems differ in several hardware and software characteristics as well as in the level of automation, features which can influence the accuracy of transferring the quantum-standard voltage value to a calibrated instrument. The comparison was performed at 100 mV, 20 mV and 12 mV, at frequencies between 2.5 kHz and 100 kHz. An electronically-aided thermal transfer standard was used as a travelling standard. At the most accurate voltage and frequency point, 100 mV at 2.5 kHz, both laboratories agreed to better than 1 part in 10^6. |
---|
Date de publication | 2012-11 |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Identificateur | S0263224112001170 |
---|
Numéro NPARC | 21268815 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 64e2ba41-4b52-496f-8582-e61ef10a02eb |
---|
Enregistrement créé | 2013-11-14 |
---|
Enregistrement modifié | 2020-04-21 |
---|