| Auteur | Rechercher : Sanchez, C.1 |
|---|
| Affiliation | - Conseil national de recherches Canada. Science des mesures et étalons
|
|---|
| Format | Texte, Article |
|---|
| Conférence | Conference on Precision Electromagnetic Measurements, July 8-13, 2018, Paris, France |
|---|
| Sujet | cryogenic current comparator; quantum hall resistance; resistance bridge; SQUIDs |
|---|
| Résumé | This paper describes the main sources of error in the NRC Cryogenic Current Comparator (CCC) and Quantum Hall Resistance Standard (QHR) systems and reports their estimated uncertainty. The CCC type B uncertainty is evaluated to be about 0.26 parts in 109 with the largest contribution being the effect of a noise-induced offset in the Superconducting Quantum Interference Device (SQUID). The uncertainty of the QHR system is estimated at 0.28, with comparable contribution from leakage resistances between the leads and finite dissipation on the QHR sample. |
|---|
| Date de publication | 2018-07 |
|---|
| Maison d’édition | The Conference |
|---|
| Dans | |
|---|
| Langue | anglais |
|---|
| Publications évaluées par des pairs | Oui |
|---|
| Numéro NPARC | 23004098 |
|---|
| Exporter la notice | Exporter en format RIS |
|---|
| Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
|---|
| Identificateur de l’enregistrement | 6aecdbf7-f425-4f1c-99e7-cf8ff4e4fe8f |
|---|
| Enregistrement créé | 2018-09-27 |
|---|
| Enregistrement modifié | 2020-03-16 |
|---|