Téléchargement | - Voir la version finale : Quality control in preparing masonry mortar (PDF, 1.8 Mio)
|
---|
DOI | Trouver le DOI : https://doi.org/10.4224/20378627 |
---|
Auteur | Rechercher : Davison, J. I.1 |
---|
Affiliation | - Conseil national de recherches du Canada
|
---|
Format | Texte, Rapport technique |
---|
Description physique | 6 p. |
---|
Sujet | Mortier; Maçonnerie; mortar; standards; quality control; safety factors |
---|
Résumé | Quality control during mortar preparation can be improved by adherence to recommendations in Canadian Standards Association Standard A179 concerning on-site storage of materials, batching, and mixing procedures. The Specification contains a test method that will assist the mixer operator in determining sand bulking, and methods that the inspector can use to prepare specimens for compression tests and to determine the ratio between aggregate and cementitious material in fresh mortar. Proper use of these procedures and test methods will ensure more consistent mortar properties, improve the image of masonry in the eyes of the designer, minimize embarrassing colour variations, and could ultimately contribute to the reduction of safety factors in design codes. |
---|
Date de publication | 1977-09 |
---|
Maison d’édition | National Research Council of Canada. Division of Building Research |
---|
Série | |
---|
Traduction de | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Non |
---|
Numéro du CNRC | NRC-IRC-1311 |
---|
Numéro NPARC | 20378627 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | 93ba7acd-4e0b-4308-8b4f-71b61fdc413f |
---|
Enregistrement créé | 2012-07-24 |
---|
Enregistrement modifié | 2023-01-19 |
---|