DOI | Trouver le DOI : https://doi.org/10.1049/el.2011.3369 |
---|
Auteur | Rechercher : Ventrudo, B. F.1; Rechercher : Storey, C.1; Rechercher : Gupta, J. A.1; Rechercher : Bezinger, A.1 |
---|
Affiliation | - Conseil national de recherches du Canada. Institut des sciences des microstructures du CNRC
|
---|
Format | Texte, Article |
---|
Résumé | The HF gas detection sensitivity of GaSb-based distributed feedback lasers was studied in order to evaluate the potential use of operating temperature to control the laser output power in field applications. Measurements were made in the 2f wavelength modulation spectroscopy mode to monitor a prominent HF absorption feature at 2396 nm. An Allan variance analysis indicates that the best sensitivity is obtained when a larger thermoelectric current is applied to maintain temperature control by actively heating or cooling the laser. The reduced detection sensitivity for a setpoint near the ambient laser operating temperature is similar to that obtained without active temperature control. |
---|
Date de publication | 2012-01-19 |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21268967 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | b5b92450-949b-4416-b45f-654ce6701a59 |
---|
Enregistrement créé | 2013-11-28 |
---|
Enregistrement modifié | 2020-04-21 |
---|