Téléchargement | - Voir le manuscrit accepté : Effect of detector nonlinearity and image persistence on CARS derived temperatures (PDF, 1.7 Mio)
|
---|
Auteur | Rechercher : Snelling, D. R.1; Rechercher : Smallwood, G. J.1; Rechercher : Parameswaran, T.1 |
---|
Affiliation | - Conseil national de recherches du Canada. Institut de technologie des procédés chimiques et de l'environnement du CNRC
|
---|
Format | Texte, Article |
---|
Résumé | The image persistence of self-scanning photodiode arrays (IPDA) incorporating P-20 phosphor-based intensifiers is shown to make them unsuitable for single-pulse CARS temperature measurements in turbulent combustion. Correcting CARS flame spectra for the nonlinear response of the IPDA detectors increases CARS derived temperatures about 3-6%. This error is partially offset by correcting for the perturbations in the N2 vibrational population resulting from stimulated Raman pumping. The effect of these population perturbations on CARS-derived temperatures is determined. CARS flame spectra obtained with uncorrelated pump beams that are corrected for IPDA nonlinearity and stimulated Raman pumping are shown to give temperatures in good agreement with combined thermocouple/sodium line-reversal measurements. |
---|
Date de publication | 1989 |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro du CNRC | NRCC 52302 |
---|
Numéro NPARC | 16296155 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | bf569d3f-ab5e-4105-afcb-019dac7e5872 |
---|
Enregistrement créé | 2010-11-04 |
---|
Enregistrement modifié | 2020-05-08 |
---|