DOI | Trouver le DOI : https://doi.org/10.1080/10618560600916981 |
---|
Auteur | Rechercher : Huang, S.; Rechercher : Islam, M.; Rechercher : Liu, P. |
---|
Format | Texte, Article |
---|
Sujet | numerical simulation; multistage centrifugal pump; impeller and diffuser; turbulent flow; reverse flow |
---|
Résumé | A three-dimensional turbulent flow through a multistage centrifugal pump is numerically simulated using a commercial CFD software package. The simulation and analysis include flow fields in rotating impeller and stationary diffuser and is completed in a multiple reference frame. The standard - turbulence model is applied. The analysis of the simulation reveals that the reverse flows exist in the zone near the impeller exit and diffuser entrance, resulting in flow field asymmetric and unsteady. There is a considerable interference on velocity field at impeller exit due to the interaction between impeller blades and diffuser vanes. The hydraulic performance is connected and evaluated with the 3-D computational flow field. The current computation is verified by comparing predicted and measured head. |
---|
Date de publication | 2006 |
---|
Dans | |
---|
Publications évaluées par des pairs | Oui |
---|
Identificateur | IR-2006-25 |
---|
Numéro du CNRC | NRC-IOT-6404 |
---|
Numéro NPARC | 8895080 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | db2a7420-04af-4e55-bd41-f758fb327465 |
---|
Enregistrement créé | 2009-04-22 |
---|
Enregistrement modifié | 2020-04-22 |
---|