DOI | Trouver le DOI : https://doi.org/10.14339/AGARD-AGARDCP565-pdf |
---|
Auteur | Rechercher : Komorowski, J. P.1; Rechercher : Krishnakumar, S.1; Rechercher : Gould, Ronald W (Ron)1; Rechercher : Bellinger, Nicholas C (Nick)1; Rechercher : Karpala, F.; Rechercher : Hageniers, O. |
---|
Affiliation | - Conseil national de recherches du Canada. Institut de recherche aérospatiale du CNRC
|
---|
Format | Texte, Article |
---|
Conférence | 79th Meeting of the AGARD Structures and Materials Panel on Corrosion Detection and Management of Advanced Airframe Materials, Oct. 5-6, 1994, Seville, Spain |
---|
Sujet | Aircraft Structures; Corrosion; Damage; Inspection; Nondestructive Tests; Retroreflection; Surface Distortion; Computerized Simulation; Fuselages; Mathematical Models; Transport Aircraft |
---|
Résumé | An optical double pass retroreflection surface inspection technique (D Sight) used for visualizing surface distortions, depressions or pertrusions has been adapted as a rapid, enhanced visual inspection method inspection of large external aircraft surfaces. A project to fully characterize the D Sight indications of corrosion damage in lap splices is currently active. Over 150 large transport aircraft fuselage lap splice specimens have been collected. D Sight Aircraft Inspection System - (DAIS) 250C has been developed and tested both in the laboratory and in the field. In laboratory tests lap splices retrieved from retired aircraft and subjected to accelerated corrosion and lap splices naturally corroded in-service were inspected with DAIS, eddy current, X-ray, shadow moire and subjected to tear down. It has been shown that the DAIS 250C is capable of locating corrosion pillowing indicative of a thickness loss as low as 2 percent. The first field trial of the DAIS 250C was based on two service bulletins requiring inspection of longitudinal and circumferential lap splices on the 737-200 aircraft from BS 259.5 to BS 1016. The DAIS 250C inspection, including analysis and report, took 36 man-hours. The recommended technique in the SB was close visual inspection and the time required according to the service bulletins, was 278 man-hours. |
---|
Date de publication | 1994-10-06 |
---|
Maison d’édition | NATO |
---|
Dans | |
---|
Numéro du CNRC | SMPL-1994-0072 |
---|
Numéro NPARC | 8926830 |
---|