DOI | Trouver le DOI : https://doi.org/10.1117/12.805868 |
---|
Auteur | Rechercher : MacKinnon, David1; Rechercher : Beraldin, J.-Angelo1; Rechercher : Cournoyer, Luc1; Rechercher : Blais, Francois1 |
---|
Affiliation | - Conseil national de recherches du Canada. Institut des étalons nationaux de mesure du CNRC
|
---|
Format | Texte, Article |
---|
Sujet | resolution; quality metrics; laser range imaging; laser spot scanner; 3D metrology; limit of resolvability |
---|
Résumé | In this study, laser range scanner lateral resolution is investigated for laser range scanners. A standardized method is proposed and demonstrated for quantifying the lateral surface resolvability of a laser range scanner through the use of an appropriately-designed artefact. A new metric for lateral surface resolution, the limit of surface resolvability, is presented and is obtained using what is referred to as the wedge test. The results of applying this metrics using this test method to laser range scanners is also presented. |
---|
Date de publication | 2009-01-18 |
---|
Dans | |
---|
Série | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Numéro NPARC | 21268151 |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | e42df9be-859c-430d-8abe-6d00000710e1 |
---|
Enregistrement créé | 2013-05-10 |
---|
Enregistrement modifié | 2020-04-16 |
---|