Téléchargement | - Voir les données supplémentaires : International interlaboratory compilation of trace element concentrations in the CUP-2 uranium ore concentrate standard (DOCX, 5.8 Mio)
|
---|
DOI | Trouver le DOI : https://doi.org/10.1007/s10967-022-08397-9 |
---|
Auteur | Rechercher : Denton, Joanna S.Identifiant ORCID : https://orcid.org/0000-0002-7636-0091; Rechercher : Bostick, Debra A.; Rechercher : Boulyga, Sergei F.; Rechercher : Cunningham, J. Alan; Rechercher : Dimayuga, Ike; Rechercher : Hexel, Cole R.; Rechercher : Hiess, Joe; Rechercher : Jovanovic, Slobodan V.; Rechercher : Kaye, Philip; Rechercher : Kell, Tara; Rechercher : Kelly, Fiona; Rechercher : Kinman, William; Rechercher : Kiser, Stephen; Rechercher : Lindvall, Rachel E.; Rechercher : Macsik, Zsuzsanna; Rechercher : Manard, Benjamin T.; Rechercher : Mayer, Klaus; Rechercher : Mercier, Jean-Francois; Rechercher : Samuleev, Pavel; Rechercher : Saull, Patrick R. B.1; Rechercher : Shi, Youqing; Rechercher : Steiner, Robert. E.; Rechercher : Ticknor, Brian W.; Rechercher : Totland, Marina; Rechercher : Varga, Zsolt; Rechercher : Wallenius, Maria; Rechercher : Wylie, E. Miller |
---|
Affiliation | - Conseil national de recherches du Canada. Centre de recherche en métrologie
|
---|
Bailleur de fonds | Rechercher : U.S. Department of Energy; Rechercher : Atomic Weapons Establishment; Rechercher : Canadian Safety and Security Program; Rechercher : Atomic Energy of Canada, Ltd |
---|
Format | Texte, Article |
---|
Résumé | A nuclear forensics investigation involving a uranium ore concentrate relies on accurate and precise analysis of impurities. Analytical data defensibility requires the use of reference materials as part of quality control. This study presents a compilation of trace element concentration results of the CUP-2 Uranium Ore Concentrate Standard measured by 11 different laboratories. The laboratories employed various dissolution methods, analytical preparation methods, and instrumental platforms. The data presented here contain concentrations of 66 impurities with up to 138 individual data points for each impurity. Consensus values have been assigned to each impurity following a statistical analysis of the data set. |
---|
Date de publication | 2022-11-11 |
---|
Maison d’édition | Springer Nature |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | f5b381d4-2dbd-48e8-9839-f2e97d8efeb3 |
---|
Enregistrement créé | 2023-08-30 |
---|
Enregistrement modifié | 2023-08-30 |
---|