Téléchargement | - Sera disponible ici le 31 août 2024
|
---|
DOI | Trouver le DOI : https://doi.org/10.1088/1681-7575/acee82 |
---|
Auteur | Rechercher : Eves, B. J.1Identifiant ORCID : https://orcid.org/0000-0003-2481-0334; Rechercher : Leroux, I. D.1; Rechercher : Cen, A. J.1 |
---|
Affiliation | - Conseil national de recherches du Canada. Centre de recherche en métrologie
|
---|
Format | Texte, Article |
---|
Sujet | phase shifting interferometry; plane angle; deformable mirror |
---|
Résumé | A phase shifting Twymann-Green interferometer for the measurement of plane angle has been developed and characterized using a small-angle generator directly traceable to the definition of the radian. The impact of surface form on the measured angle was explored using a simple deformable mirror. The angle sensitivity of the interferometer did not depend upon the surface form. Comparison of the calibrations of two polygons and two angle gauge blocks by both the angle interferometer and a commercial autocollimator showed excellent agreement with normalized errors of less than 0.4. The standard uncertainty for the angle interferometer when measuring the polygons was less than 0.02. |
---|
Date de publication | 2023-08-31 |
---|
Maison d’édition | IOP Publishing |
---|
Dans | |
---|
Langue | anglais |
---|
Publications évaluées par des pairs | Oui |
---|
Exporter la notice | Exporter en format RIS |
---|
Signaler une correction | Signaler une correction (s'ouvre dans un nouvel onglet) |
---|
Identificateur de l’enregistrement | f7d56515-e8f6-41cc-b351-ce59f59f6844 |
---|
Enregistrement créé | 2024-01-09 |
---|
Enregistrement modifié | 2024-01-11 |
---|