Download | - View accepted manuscript: The inverse-square gamma-irradiation anomaly of the nuclear enterprise 2575 large-volume ionisation chamber (PDF, 173 KiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.1093/rpd/ncu306 |
---|
Author | Search for: Bielajew, Alex F.; Search for: Tessier, Frederic1; Search for: Gamal, Islam El1 |
---|
Affiliation | - National Research Council of Canada. Measurement Science and Standards
|
---|
Format | Text, Article |
---|
Abstract | The Nuclear Enterprises (Model 2575) 600 cc ionisation chamber is examined to discover the cause of its anomalous behaviour in inverse-square stability measurements. Measurements and Monte Carlo calculations are employed to isolate the cause of the discrepancy. It is found that most of the effect is due to the long photon attenuation pathlengths in the long side wall of the instrument. A phenomenological procedure, based on measurements, is proposed to correct for the anomaly. The procedure results in inverse-square stability to within 0.5% over a range of 1-7 meters. |
---|
Publication date | 2014-10-13 |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 21274933 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 02126d7b-2628-4658-938b-ff44a94e578b |
---|
Record created | 2015-05-01 |
---|
Record modified | 2020-06-04 |
---|