DOI | Resolve DOI: https://doi.org/10.1109/CPEM49742.2020.9191750 |
---|
Author | Search for: Granger, G.1; Search for: Kurten Ihlenfeld, Waldemar G.1 |
---|
Affiliation | - National Research Council of Canada. Metrology Research Centre
|
---|
Format | Text, Article |
---|
Conference | 2020 Conference on Precision Electromagnetic Measurements (CPEM 2020), August 24-28, 2020, Denver (Aurora), Colorado |
---|
Physical description | 2 p. |
---|
Subject | AC-DC difference; AC voltage; digital sampling; Josephson Arbitrary Waveform Synthesizer; Josephson voltage standard; measurement uncertainty |
---|
Abstract | Using a Josephson Arbitrary Waveform Synthesizer (JAWS), we measure the AC-DC difference of a sampling digital voltmeter (SDVM) through direct sampling and subsampling. We also perform direct and differential sampling measurements of the amplitude of an AC voltage source, built at the National Research Council Canada (NRC), against the JAWS. Such calibrations of the SDVM and NRC voltage source could help maintain AC voltage traceability in between JAWS operations. |
---|
Publication date | 2020-09-10 |
---|
Publisher | IEEE |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 146e7c4c-4717-438f-bfcc-9e845f497dee |
---|
Record created | 2020-11-16 |
---|
Record modified | 2022-07-28 |
---|