DOI | Resolve DOI: https://doi.org/10.1016/j.firesaf.2012.08.006 |
---|
Author | Search for: Cree, D.; Search for: Chowdhury, E. U.; Search for: Green, M. F.; Search for: Bisby, L. A.; Search for: Bénichou, N.1 |
---|
Affiliation | - National Research Council of Canada. Construction
|
---|
Format | Text, Article |
---|
Subject | Fire test; FRP; Insulation; Reinforced concrete column; High temperature; Full-scale |
---|
Abstract | This research investigates the fire performance of one circular and one square reinforced concrete column strengthened with a fibre reinforced polymer (FRP) wrap and covered with a unique supplemental fire protection system. An experimental full-scale fire resistance test was conducted at the National Research Council of Canada. The insulated and strengthened FRP wrapped columns were exposed to the ULC-S101 standard fire and both columns obtained fire endurance ratings of over 4 h. Details of the fire endurance experiment on both columns are described in this paper. Additionally, numerical models developed specifically for circular and square columns are validated against the experimental results. |
---|
Publication date | 2012-11 |
---|
In | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
Identifier | S0379711212001105 |
---|
NPARC number | 21268758 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | 2548007c-9a57-4e43-9cf7-f5cb956bff0e |
---|
Record created | 2013-11-12 |
---|
Record modified | 2020-04-21 |
---|