Download | - View accepted manuscript: A computer-controlled system for calibrating high voltage revenue metering systems under actual operating conditions of high voltage and sinusoidal/non-sinusoidal voltage and current waveforms (PDF, 549 KiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.1109/CPEM.2010.5544827 |
---|
Author | Search for: So, E.1; Search for: Arseneau, R.1; Search for: Bennett, D.1; Search for: Frigault, M.1 |
---|
Affiliation | - National Research Council of Canada. NRC Institute for National Measurement Standards
|
---|
Format | Text, Article |
---|
Conference | 2010 Conference on Precision Electromagnetic Measurements (CPEM 2010), June 13-18, 2010, Daejeon, South Korea |
---|
Abstract | The development of a computer-controlled system for the calibration of high voltage revenue metering systems under actual operating conditions of high voltage and sinusoidal/non-sinusoidal voltage and current waveforms will be described. Measurements can be made at any power factor from zero lag through unity, at voltages up to 100 kV line-to-ground voltage and currents up to 2000 A. The magnitude and phase uncertainties (k=2) are estimated to be not more than 50 μW/VA and 50 μrad, and 100 μW/VA and 100 μrad for sinusoidal and non-sinusoidal conditions, respectively. |
---|
Publication date | 2010-06-01 |
---|
In | |
---|
Series | |
---|
Language | English |
---|
Peer reviewed | Yes |
---|
NPARC number | 17131341 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | b80aaf68-26e3-453f-aec3-ceaeb695c79c |
---|
Record created | 2011-03-11 |
---|
Record modified | 2020-04-17 |
---|