Download | - View accepted manuscript: Investigation of systematic errors of an AC Jospehson Voltage Standard (PDF, 1.2 MiB)
|
---|
DOI | Resolve DOI: https://doi.org/10.1109/CPEM.2012.6250646 |
---|
Author | Search for: Filipski, Piotr S.1 |
---|
Affiliation | - National Research Council of Canada. NRC Institute for National Measurement Standards
|
---|
Format | Text, Article |
---|
Conference | 2012 Conference on Precision Electromagnetic Measurements (CPEM 2012), 1-6 July 2012, Washington, DC, USA |
---|
Subject | Josephson effect; calibration; digital-analog conversion; superconducting arrays; voltage measurement; signal synthesis |
---|
Abstract | This paper presents results of experiments quantifying two systematic errors associated with the calibrations by use of an AC Josephson Voltage Standard: the change in the voltage leads error with the change in the level of probe immersion in the liquid helium, and the effect of the internal inductance of a Josephson array. The measurements were performed at frequencies 100 kHz and above, however, they can be used in evaluating an error budget at lower frequencies. |
---|
Publication date | 2012-07-30 |
---|
In | |
---|
Language | English |
---|
Peer reviewed | No |
---|
NPARC number | 20955690 |
---|
Export citation | Export as RIS |
---|
Report a correction | Report a correction (opens in a new tab) |
---|
Record identifier | bea7f81e-79a1-48cf-a708-db1960e23d61 |
---|
Record created | 2012-11-14 |
---|
Record modified | 2020-04-21 |
---|